Induction units (Active Chilled Beams)
Source: eKapija
Thursday, 15.12.2022.
03:11


(Photo: Trox)

In rooms with high heat loads, air-water systems represent an energy-efficient alternative to only air systems, i.e. systems in which air is the only working fluid. Bearing in mind that in air-water systems the air in the room is heated or cooled via heat exchangers, the heating and cooling capacities are provided independently of the required amount of fresh air
Fresh air from the air handling unit is introduced into the room through induction units as an addition to cooling or heating, which is provided on the water side. Since the air in this system is introduced only in the amount needed to provide the necessary portions of fresh air per user, the amount of air introduced is significantly reduced compared to only air systems.
(Photo: Trox)

Induction units work by inducing the air from the room through the grille on the induction device, passing through the heat exchanger, where it is heated or cooled as needed, and then mixed with the prepared fresh air in the plenum box and then through the slots located on two or on all four sides of the device enters the room.
(Photo: Trox)

No additional fans are needed for the distribution of secondary air, which results in lower energy consumption and significantly lower noise compared to air-water systems that basically have a fan coil.
(Photo: Trox)

Additional advantages of induction units are:
• long life (up to 30 years), because induction units have no moving parts and no parts that could wear out and require replacement;
• easy maintenance (usual cleaning twice a year is recommended as part of regular maintenance; for cleaning purposes, access is from the bottom, i.e. from the room);
• energy efficient;
• low noise level (it is possible to reach below 25 dB of sound pressure)
• space saving (low constructions; about 2/3 less need for air ducts than with completely air systems);
• optimal thermal comfort of the user.
• long life (up to 30 years), because induction units have no moving parts and no parts that could wear out and require replacement;
• easy maintenance (usual cleaning twice a year is recommended as part of regular maintenance; for cleaning purposes, access is from the bottom, i.e. from the room);
• energy efficient;
• low noise level (it is possible to reach below 25 dB of sound pressure)
• space saving (low constructions; about 2/3 less need for air ducts than with completely air systems);
• optimal thermal comfort of the user.
(Photo: Trox)

In addition to ceiling installation, the German company TROX also produces induction units in variants for parapet installation and floor installation.
(Photo: Trox)

(Photo: Trox)

Induction units are the right solution when you want to save energy and at the same time provide maximum comfort to users in a comfortable and modern environment.
We are at your disposal to choose the type of induction device that best suits your needs.
TROX Austria – Serbia office
We are at your disposal to choose the type of induction device that best suits your needs.
TROX Austria – Serbia office
44 Kralja Petra St
11000 Belgrade
trox-rs@troxgroup.com
Companies:

Tags:
Trox
induction units
smoke detectors
sprinklers
ventilation and airconditioning systems
energy conservation
energy efficiency
special edition newsletter
Interior and Exterior Solutions for a Modern Practical and Comfortable Space
Comments
Your comment
Most Important News
Full information is available only to commercial users-subscribers and it is necessary to log in.
Follow the news, tenders, grants, legal regulations and reports on our portal.
Registracija na eKapiji vam omogućava pristup potpunim informacijama i dnevnom biltenu
Naš dnevni ekonomski bilten će stizati na vašu mejl adresu krajem svakog radnog dana. Bilteni su personalizovani prema interesovanjima svakog korisnika zasebno,
uz konsultacije sa našim ekspertima.